264
this post was submitted on 25 May 2024
264 points (93.7% liked)
Technology
59589 readers
2891 users here now
This is a most excellent place for technology news and articles.
Our Rules
- Follow the lemmy.world rules.
- Only tech related content.
- Be excellent to each another!
- Mod approved content bots can post up to 10 articles per day.
- Threads asking for personal tech support may be deleted.
- Politics threads may be removed.
- No memes allowed as posts, OK to post as comments.
- Only approved bots from the list below, to ask if your bot can be added please contact us.
- Check for duplicates before posting, duplicates may be removed
Approved Bots
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
It's not actually 230V in Europe, it's 400V. Between each pair of the three phases, that is, between phase and neutral there's 230V. (If there's a neutral and you don't create it locally, different topic).
...but I'd actually have different doubts about using the whole thing in the US: Your plugs. Schukos aren't meant for the purpose and only code for up to 800W when used to backfeed. That's almost 1/5th of their 1 hour continuous rating. With those flimsy tinfoil plugs you have you're going to need special outlets, or hard-wire them.